产品展示 / products 您的位置:网站首页 > 产品展示 > > 美国omega流量计 > FTB-934流量计 美国omega

FTB-934流量计 美国omega

简要描述:FTB-934流量计 美国omega,美国omega流量仪表 一手货源,优势批发

  • 产品型号:
  • 厂商性质:代理商
  • 更新时间:2025-05-23
  • 访  问  量:781
详情介绍

FTB-934流量计 美国omega

带外螺纹NPT接头的滚珠轴承气体涡轮机流量计
FTB-930
带外螺纹NPT接头的滚珠轴承气体涡轮机流量计
±1% of Reading Accuracy 
Ball Bearing Design for Economy 
440C Bearing Retainers for Durability 
Ball Bearings Field Replaceable Without Loss of Calibration 
Deflector Cones Stabilize Low Mass Rotor for Increased Bearing Life 
NIST Certificate Supplied Standard


The OMEGA? FTB-930 & FTB-940 Series turbine meters have male NPT end fittings for easy connections. They are suitable for use with gases with a minimum density of 0.025 lb/ft 3 (air at STP is 0.0752 lb/ft 3 ).These units come supplied with a mating 2-wire connector and can be supplied with integrally mounted FLSC-60 Series signal conditioners to provide 4-20 mA, 0-5 V, or amplified pulse outputs. These turbine gas meters are intended for clean service only; where there is any doubt about the fluid, strainers are recommended.
OMEGA? precision turbine gas flowmeters are designed to measure actual cubic feet or actual volume passing through the meter. Before sizing a flowmeter, it is necessary to convert flow units (i.e., SCFM, LPM, etc.) to actual units. To convert to actual measured volume (ACFM) from standard volume (SCFM), use the following formula:
ACFM = SCFM x 14.7/Pa x Ta/530
where:
ACFM = Actual cubic feet per minute of measured gas flow
SCFM = Standard cubic feet per minute gas flow
Pa = Operating pressure (psia) in = (psig + 14.7)
Ta = Temperature in degrees, Rankine = (°F + 460)
SPECIFICATIONS
Accuracy: ±1.0% of reading
Repeatability: ±0.25%
Materials of Construction:
Body: 304/316 stainless steel
Rotor: 17-4 PH SS
Bearings: 440C stainless steel
Output: 30 mV p-p sinewave min.


产品型号/产品描述
FTB-931B 0.35-3.5 Max Linear Range (AFCM); 1/2 End Connections MNPT (in)
FTB-932 .75-5 Max Linear Range (ACFM); 1/2 End Connections MNPT (in)
FTB-933 1-10 Max Linear Range (ACFM); 1/2 End Connections MNPT (in)
FTB-934 2-20 Max Linear Range (ACFM); 1/2 End Connections MNPT (in)
FTB-935 2.5-28 Max Linear Range (ACFM); 3/4 End Connections MNPT (in)
FTB-936 4-60 Max Linear Range (ACFM); 1 End Connections MNPT (in)
FTB-937 6-100 Max Linear Range (ACFM); 1 1/4 End Connections MNPT (in)
FTB-938 8-130 Max Linear Range (ACFM); 1 1/2 End Connections MNPT (in)
FTB-939 15-250 Max Linear Range (ACFM); 2 End Connections MNPT (in)
FTB-940 25-450 Max Linear Range (ACFM); 2 1/2 End Connections MNPT (in)
FTB-941 40-650 Max Linear Range (ACFM); 3 End Connections MNPT (in)
Signal Conditioners (Order as a System for factory Scaling on FLSC-61 and FLSC-62, For Example: SYS/FTB-931/FLSC-62)
FLSC-61 0-5/0-10 Volt output
FLSC-62A 4-20 mA output
FLSC-64 Amplifier (Squarewave Output)
Accessories
PSR-24S Regulated power supply, US plug, 90-264 Vac input, 24 Vdc output, 400 mA, screw terminals, UL
注释: Comes complete with operator’s manual and NIST Certificate for air.
To order turbine meters with integral signal conditioners, specify model as a system such as : SYS/FTB-932/FLSC-62A. Omega will scale the signal conditioner with the appropriate calibration information from the turbine meter specified.
No other calibrations are available.
Compatible Meters: DPF701, DPF402, DPF70 with FLSC-AMP, DPF10, DPF500, FC20, 21, 22