欢迎光临深圳市鑫博恒业科技有限公司网站!
全国服务咨询热线:

13823144468

产品展示 / products 您的位置:网站首页 > 产品展示 > > 美国omega流量计 > LVC-E56电导率液位开关 美国omega

LVC-E56电导率液位开关 美国omega

简要描述:LVC-E56电导率液位开关 美国omega,美国omega流量仪表 一手货源,优势批发

  • 产品型号:
  • 厂商性质:代理商
  • 更新时间:2025-05-23
  • 访  问  量:1795
详情介绍

LVC-E56电导率液位开关 美国omega

低成本电导率液位开关系统,仅用于液体
LVC Series, LVC500 Series
低成本电导率液位开关系统,仅用于液体
没有移动部件的寿命
广泛的化学相容性
用于导电液体的作品
SPDT继电器输出
现场*可选
查看继电器状态透明盒

Series LVC500 electronic level controls should be used whenever a liquid level needs to be maintained, such as pumping down an industrial sump, or indicated, such as a holding tank high level alarm. A system consists of three components; 1) Cut-to-length threaded electrode rods. 2) Single or multi-electrode holder. 3) Remote electronic module(s).
The LVC500 Series operates on a simple conductance principle whereby a small electrical current is passed through the conductive liquid between two electrodes or an electrode and metallic tank wall. For those applications requiring a separate start and stop point, a single control module, plus two electrodes and tank reference are required. When several applications or levels are necessary within a single tank, an electrode is needed for each level (plus tank reference), plus a multi-electrode holder and a control module for each differential or single level application.
Note:
Always treat hazardous areas with respect! If the electrodes or float switch is located in a hazardous area an intrinsically safe control module must be used. Intrinsically safe controls must be installed by experienced personnel familiar with intrinsic safety wiring, and installation must be in accordance with the National Electrical Code (NEC). The control must be mounted in a non-hazardous location with the wiring to the level probes or float switch going into the hazardous atmosphere. Intrinsically safe wiring must be separated from non-intrinsically safe wiring, and the length of your 14 or 16 gage copper wire must not exceed the specifications listed in the current installation manual. Consult your local electrical code inspector for further details.
 

产品型号/产品描述
Electrodes
LVC-E11 303SS, 12 "
LVC-E12 303SS, 24"
LVC-E13 303SS, 36"
LVC-E14 303SS, 48"
LVC-E15 303SS, 60"
LVC-E16 303SS, 72"
LVC-E51 316SS, 12 "
LVC-E52 316SS, 24"
LVC-E53 316SS, 36"
LVC-E54 316SS, 48"
LVC-E55 316SS, 60"
LVC-E56 316SS, 72''
Threaded Single Electrode Holder
LVC-S3 3/8 MNPT for 1 LVC-E electrode, open terminal, 316 SS/PTFE
Threaded Multi-Electrode Assemblies (Includes Junction Box)
LVC-N1-SS Stainless steel, 1 MNPT, for 1 LVC-E electrode
LVC-N2-SS Stainless steel, 2 MNPT, for 2 LVC-E electrodes
LVC-N3-SS Stainless steel, 2 MNPT, for 3 LVC-E electrodes
LVC-N4-SS Stainless steel, 2-1/2 MNPT, for 4 LVC-E electrodes
LVC-N5-SS Stainless steel, 3 MNPT, for 5 LVC-E electrodes
LVC-N6-SS Stainless steel, 3 MNPT, for 6 LVC-E electrodes
LVC-N7-SS Stainless steel, 3 MNPT, for 7 LVC-E electrodes
LVC-N1-BR Brass, 1 MNPT, for 1 LVC-E electrode
LVC-N2-BR Brass, 2 MNPT, for 2 LVC-E electrodes
LVC-N3-BR Brass, 2 MNPT, for 3 LVC-E electrodes
LVC-N4-BR Brass, 2-1/2 MNPT, for 4 LVC-E electrodes
LVC-N5-BR Brass, 3 MNPT, for 5 LVC-E electrodes
LVC-N6-BR Brass, 3 MNPT, for 6 LVC-E electrodes
LVC-N7-BR Brass, 3 MNPT, for 7 LVC-E electrodes
LVC-N1-C Cast iron, 1 MNPT, for 1 LVC-E electrode
LVC-N2-C Cast iron, 2 MNPT, for 2 LVC-E electrodes
LVC-N3-C Cast iron, 2 MNPT, for 3 LVC-E electrodes
LVC-N4-C Cast iron, 2-1/2 MNPT, for 4 LVC-E electrodes
LVC-N5-C Cast iron, 3 MNPT, for 5 LVC-E electrodes
LVC-N6-C Cast iron, 3 MNPT, for 6 LVC-E electrodes
LVC-N7-C Cast iron, 3 MNPT, for 7 LVC-E electrodes
Flanged Multi-Electrode Assemblies (Includes Junction Box)
LVC-F1-SS Stainless steel, 1", for 1 LVC-E electrode
LVC-F2-SS Stainless steel, 2", for 2 LVC-E electrodes
LVC-F3-SS Stainless steel, 2", for 3 LVC-E electrodes
LVC-F4-SS Stainless steel, 2-1/2", for 4 LVC-E electrodes
LVC-F5-SS Stainless steel, 3", for 5 LVC-E electrodes
LVC-F6-SS Stainless steel, 3", for 6 LVC-E electrodes
LVC-F7-SS Stainless steel, 3", for 7 LVC-E electrodes
LVC-F1-CI Cast iron, 1", for 1 LVC-E electrode
LVC-F2-CI Cast iron, 2", for 2 LVC-E electrodes
LVC-F3-CI Cast iron, 2", for 3 LVC-E electrodes
LVC-F4-CI Cast iron, 2-1/2", for 4 LVC-E electrodes
LVC-F5-CI Cast iron, 3", for 5 LVC-E electrodes
LVC-F6-CI Cast iron, 3", for 6 LVC-E electrodes
LVC-F7-CI Cast iron, 3", for 7 LVC-E electrodes
Standard Relay Electronics
LVC511 10 Amps resistive at up to 120 Vac, 8-pin socket
LVC512 10 Amps resistive at up to 120 Vac, 11-pin socket
LVC521 10 Amps resistive at up to 120 Vac, open circuit board
LVC551 8 Amps resistive at up to 120 Vac, FM listed
LVC552 8 Amps resistive at up to 120 Vac, UL listed
LVC553 8 Amps resistive at up to 120 Vac, CSA listed

注释: Comes complete with operator's manual.
Direct action standard; for inverse action, add suffix "-INV" to model number, no additional cost.
Inverse normally used for pump up or low level applications.

LVC-E56电导率液位开关 美国omega
 

相关产品:

LV-1201非磁性液位开关 美国omega



留言询价

留言框

  • 产品:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 省份:

  • 详细地址:

  • 补充说明:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7
技术支持:化工仪器网   sitemap.xml   管理登陆
© 2025 版权所有:深圳市鑫博恒业科技有限公司( www.xbtes.com)   备案号:粤ICP备09037369号